Case Study: No Soap Functions, Tire Shine Stuck Out

Home » Troubleshooting / Case Studies » Case Study: No Soap Functions, Tire Shine Stuck Out
Description of Problem:

No soap functions spraying and/or the tire shine unit is stuck in out position.

 

Things to Check:

This problem generally indicates a lack of air pressure in the system.

 

1. Confirm Air Pressure at the Detergent POD.
On the air pressure regulator you should have at least 80PSI.

 

2. If no air pressure indicated at POD, confirm air pressure at the air compressor in the back room. The air compressor is typically locatred in the upstairs mezzanine

 

3. If no air pressure indicated at air compressor, try to reset the air compressor by pressing reset button on the front of the unit, or by turning it off and back on again.

 

Note: The newer style air compressors have 2 switches: the big red one is the main power switch and the small black switch below it initializes the compressor.

 

4. Once the air compressors start running allow them to build up pressure and test to see if soap functions are working properly. If not, please call for support.

.